0
Items : 0
Subtotal :  0.00
View CartCheck Out
Chennai
Chennai
Singapore
Mumbai
+91 98848 35702 Mon - Fri 09:00 - 18:30 766/1, TEZ, Sakthi Towers 1, Anna salai, Chennai 600 002.
+65 9324 8815 Mon - Fri 09:00 - 18:30 171, TRAS STREET 07 175 UNION BUILDING, SINGAPORE 079025.
+91 98848 35702 Mon - Fri 09:00 - 18:30 5, Powai Lake Heights, Mumbai 400 072
Ceritified
ISO 9001:2008
The Best
#1 in India
Number #1
AUTOMATION SOLUTION PROVIDER
Talk to an Expert
0
Items : 0
Subtotal :  0.00
View CartCheck Out
csm_Freeze_Point_Analyzer_Model_P-800LT__Low_Temperature_d1c34da298csm_Freeze_Point_Analyzer_Model_P-800LT__Low_Temperature_d1c34da298

Freeze Point Analyzer

Model P-800LT
P-800LT-1.00
  • Operating range -125 to 25 °C (-193 to 77 °F)
  • Straight path absorbance & 90° back-scatter detection
  • Rapid analysis cycle of 15 minutes or less
  • Superior repeatability of less than 0.5°F (0.25°C)
  • Internal Cryo chiller cools to -125°C without external cooling system
  • No Sample Recovery System needed, can return directly to process
  • Stream switching and validation
  • Remote diagnostics over IP
Description
Technical Data
Manuals/Operating Instructions/Guides
Data Sheets
Brochures

To remain competitive, today’s refiners must employ all optimization and product control techniques available. The use of online physical property analyzers is one of the key features to reach those objectives because they measure important quality properties in the process directly.The freeze point is the temperature at which the last of the wax crystals disappear when warming the sample, after first reaching the Cloud Point temperature.

Marking

Class I, Division 1, Group B, C and D.Ex db IIB T6 GbEx db IIB T6 Gb

Ambient Temperature

T6

Certification
  • IECEx Certificate of Conformity: EN
  • EU-TYPE EXAMINATION CERTIFICATE: EN
  • Certificate of Compliance: EN

Technical Data

Technology Automatic optical detection, absorbance or reflectance
Method Correlates with ASTM D2386
Measuring cycle Typical is less than 15 minutes
Analog outputs Freeze Point, cell temperature, optical signals
Digital outputs Freeze point alarm, analyzer fault, come read (programmable)
Digital inputs customer alarm, remote standby, stream switch, validation (dry contact)
Display 7″ color graphics
Weight approximately 340 kg (750 lbs)
Dimensions Approximately 940 x 1803 x 762 mm (37 x 71 x 30 inches)
MODBUS interface TCP/IP or Serial/RTU MODBUS output available

Manuals/Operating Instructions/Guides

Data Sheets

Brochures